Fluke 1587 FC 2-in-1 1000V 2GΩ True-RMS Insulation Resistive Multimeter

0 out of 5 stars
No review yetQty | Price | Discount |
---|---|---|
1 | NaN | |
3 | NaN | -3.3% |
5 | NaN | -4.9% |
10 | NaN | -7.4% |
Product details
Description
Fluke 1587 FC 2-in-1 1000V 2GΩ True-RMS Insulation Resistive Multimeter
Features:
- PI/DAR timing ratio test
- Live line detection prevents insulation testing when voltage exceeds 30V to enhance user protection
- VFD low-pass filter for accurate measurement of motor drive
- Automatically release capacitor voltage to enhance user protection
- Insulation test (1587 FC: 0.01MΩ to 2GΩ)
- Insulation test voltage suitable for various applications (1587 FC: 50V, 100V, 250 V, 500V, 1000V)
- AC/DC voltage, DC voltage (millivolts), AC/DC current (milliamperes), resistance(Ω), continuity
- Capacitor, diode testing, temperature, minimum/maximum value, frequency(Hz)
- Automatic shutdown to save power
- CAT III 1000V,CAT IV 600V measurement categories
- Large display screen with backlight
- A sturdy and practical hard box allows you to carry all the items needed for work
- Fluke TPAK magnetometer hooks can be used for convenient two-handed operation
Specification:
Voltage DC
Maximum voltage
1000 V
Accuracy
±(0.09% + 2)
Maximum resolution
0.001V
Voltage AC
Maximum voltage
1000 V
Accuracy
±(2% + 3)
AC bandwidth
5 kHz1
1. With low pass filter; 3 db @ 800 Hz
Maximum resolution
0.1 mV
Current DC
Maximum amps
400 mA
Amps accuracy
±(0.2% + 2)
Maximum Resolution
0.01 mA
Current AC
Maximum amps
400 mA
Amps accuracy
±(1.5% + 2) 1
1. 1 kHz bandwidth
Maximum resolution
0.01 mA
Resistance
Maximum resistance
50 MΩ
Accuracy
±(0.9% + 2)
Maximum resolution
0.1 Ω
Capacitance
Maximum capacitance
9,999 µF
Accuracy
±(1.2% + 2)
Maximum resolution
1 nF
Frequency
Maximum frequency
100 kHz
Accuracy
±(0.1% + 1)
Maximum resolution
0.01 Hz
Temperature measurement
-40.0°C to 537°C
-40.0°F to 998°F
excluding probeDiode test
Range
6 V
Resolution
1 mV
Accuracy
±(2% + 1)
Insulation Test
Minimum test current @ 1 kΩ/V
1 mA
Test voltages
50, 100, 250, 500, 1000 V
Maximum resistance per test voltage
50 V
100 V
250 V
500 V
1000 V
2 GΩ
Maximum resolution per test voltage
50 V
0.01 MΩ
100 V
0.01 MΩ
250 V
0.1 MΩ
500 V
0.1 MΩ
1000 V
0.1 MΩ
Accuracy per test voltage
50 V
±(3% + 5)
100 V
±(3% + 5)
250 V
±(1.5% + 5)
500 V
±(1.5% + 5)
1000 V
±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Package includes:
- 1 x Multimeter (without Battery)
- 1 x Remote Probe
- 1 x Test Lead and Probe
- 1 x Crocodile Clip
- 1 x K-type Thermocouple